Decoding Autoclaves: Class B vs. The Others, and the 110V vs. 220V Dilemma

If you manage a dental practice, veterinary clinic, tattoo studio, or medical office, sterilization is the backbone of your operation. Yet, when it comes time to buy a new autoclave, you are immediately confronted with an "alphabet soup" of classifications (N, S, B) and confusing electrical options.

Making the wrong choice can mean failing sterilization audits, damaging expensive instruments, or facing expensive electrical upgrades.

This guide breaks down the essential differences between autoclave classes, the pros and cons of 110V versus 220V power systems, and the one crucial factor most buyers forget until it’s too late: local support.

Part 1: The Alphabet of Sterilization (N, S, and B)

To understand autoclave classes, you first need to understand the enemy of sterilization: Air.

Steam sterilization only works if saturated steam directly contacts every surface of the instrument. If a pocket of cool air is trapped inside a hollow tube or deep within a porous sponge, the steam cannot reach that surface. That pocket of air acts as insulation, and bacteria will survive there.

The European Standard EN 13060 categorizes small steam sterilizers based on how effectively they remove this air.

1. Class N ("Naked" or Solid)

These are the simplest sterilizers, often called "gravity displacement" units. They rely on the natural principle that steam is lighter than air. As steam enters the chamber, it pushes the air down and out a drain.

  • Best for: Solid, unwrapped metal instruments.
  • The Problem: They are terrible at removing air from hollow items (like dental handpieces or cannulas) or porous items (like surgical towels). The air gets trapped inside, and those areas are not sterilized.

2. Class S ("Special")

This is the "middle child" class. Class S autoclaves are better than Class N. They often use a single-stage vacuum pump to pull some air out before the steam enters, or steam pulses to push air out.

  • Best for: Simple wrapped packs and some moderately hollow instruments, depending on the manufacturer's specifications.
  • The Problem: They are not standardized. One brand’s "S" might be better than another’s. They generally still cannot guarantee sterility for very complex, narrow-lumen instruments.

3. Class B ("Big") – The Gold Standard

Class B is the highest standard for tabletop sterilizers. These units are defined by their use of a powerful fractionated pre-vacuum.

Before steam even enters the chamber, a Class B autoclave runs a vacuum pump several times, pulling all the air out of the chamber and, crucially, out of the inside of your hollow instruments.

  • Why you need it: If you sterilize dental handpieces, laparoscopic tools, complex implant kits, or heavy double-wrapped surgical cassettes, you need Class B. It is the only way to guarantee steam penetration into the deepest recesses of complex tools.
  • The Drying Bonus: Because Class B units have powerful vacuum pumps, they also offer superior post-sterilization vacuum drying, ensuring packs come out bone-dry and ready for storage.

Part 2: The Power Struggle – 110V vs. 220V

Once you decide on the Class (likely Class B for a modern medical practice), you have to power it. Generating intense heat and steam rapidly, while simultaneously running a heavy-duty vacuum pump, requires significant energy.

The 220V Autoclave: The Industrial Workhorse

In most of the world, 220V-240V is standard. In North America, it is usually reserved for heavy appliances like dryers and ovens.

The Advantages of 220V:

  • Speed: 220V units have more available power. They heat water faster, meaning shorter overall cycle times.
  • Efficiency & Longevity: Because more power is readily available, the components (heaters and pumps) aren't working at their absolute maximum stress levels. This can sometimes translate to longer component life.
  • No Breaker Issues: A 220V unit is almost always on a dedicated circuit, so you won't trip the office lights when you start a cycle.

The Disadvantages of 220V:

  • Installation Cost: Many commercial spaces do not have spare 220V outlets. You will need to hire an electrician to install a dedicated line and the correct receptacle (NEMA 6-15R or 6-20R). This is a one-time, non-recurring expense.

The 110V Autoclave: The Convenience

These units are designed to plug into standard wall outlets in Bermuda (also in the US and Canada).

The Advantages of 110V:

  • Plug and Play: The biggest selling point. You don't need an electrician. If you are renting a space and cannot modify the electrical panel, this is your easiest option.

The Disadvantages of 110V:

  • The "Class B" Challenge: This is critical. Creating a fractionated vacuum (Class B) is energy-intensive. Trying to run a powerful heater and a powerful vacuum pump simultaneously on a standard 110V circuit is an engineering challenge.
  • Slower Speed: Because there is less power available, heat-up times are longer, making the total cycle time slower than their 220V counterparts.
  • Circuit Strain: A high-end 110V Class B autoclave will draw 12 to 15 amps. If you plug anything else into that same circuit loop (a computer, a coffee maker), you will trip the breaker. A 110V Class B unit still requires a dedicated circuit in practice.

Part 3: The "Invisible" Spec: Why Local Support is Critical

When shopping for an autoclave, it is tempting to browse online marketplaces for "bargain" units. You might find a generic brand Class B autoclave for half the price of a major brand like SciCan or Euronda.

Do not fall for this trap.

An autoclave is not a toaster; it is a high-pressure, high-heat pressure vessel with complex valves, gaskets, and electronic sensors. It will require maintenance. This is where the concept of Local Support becomes the most critical "feature" of your purchase.

1. The "Orphan" Machine Scenario

If you buy a budget imported unit online, you often have zero local support. When (not if) a gasket fails or a vacuum pump errors out, non-specialist medical technicians will often refuse to work on it because they cannot source the proprietary parts and don't have the service schematics. You are left with a 100lb paperweight.

2. The Logistics of Repair

Autoclaves are incredibly heavy (80–150 lbs). If your unit breaks and the manufacturer requires you to ship it back to a depot for repair, you face massive shipping costs and the risk of shipping damage.

  • The Advantage of Major Brands: Brands like SciCan and Euronda have networks of authorized local technicians who come to you. Lighthouse Medical is exactly such a service provider.

3. The "Loaner" Lifesaver

If your only autoclave goes down, your practice stops. You cannot treat patients. When you buy from a reputable local dealer such as Lighthouse Medical, your service contract often includes a "loaner" protocol. If your machine needs to go to the shop, the local tech drops off a loaner unit so you can keep working. An online-only vendor cannot offer this.

Summary: Which Should You Choose?

The decision usually comes down to the types of instruments you use, your facility's electrical infrastructure, and your risk tolerance regarding downtime.

Choose a Class B, 220V unit if:

  • You sterilize hollow instruments (dental handpieces, endoscopes, cannulated instruments).
  • Volume and speed are critical; you need the fastest instrument turnaround possible.
  • You have the ability to install a new electrical line.

Choose a Class B, 110V unit if:

  • You need Class B sterilization for hollow instruments.
  • You cannot install 220V wiring.
  • You can accept slower cycle times in exchange for installation convenience.

Regardless of voltage, ALWAYS ensure:

  • You buy a brand that has authorized service technicians in Bermuda.
  • You have verified that local support includes access to spare parts and loaner availability. Saving $2,000 on the purchase price is meaningless if a breakdown costs you $5,000 in lost patient appointments.
Decoding Autoclaves: Class B vs. The Others, and the 110V vs. 220V Dilemma
Mike Serebrennik February 7, 2026
Share this post